PARAMETERS
|
SAMPLING DURATION
|
SAMPLING METHODOLOGY
|
WATER QUALITY MONITORING
|
||
ph Value
|
In-situ
|
Sampling Method: Direct measurement
Apparatus: Portable pH Meter, Mettler Toledo-MP230K
|
Dissolved Oxygen (DO)
|
In-situ
|
Sampling Method: Direct measurement
Apparatus: Dissolved Oxygen Meter, Hanna (H14193)
|
NOISE MEASUREMENT
|
||
Noise
|
In-situ Reading
|
Sampling Method: Direct measurements using Sound Level Meter Type 1, Parameter to be recorded are Leq, Lmin, Lmax, L10, L50, and L90.
Apparatus: Quest 1900 Precision Sound Level Meter.
|
AMBIENT AIR QUALITY
|
||
Total Suspended Particulate (TSP)
|
24 hours
|
Sampling Method: Air sample will be collected on a pre-weight filter paper using High Volume Sampler. The mass concentration is computed by measuring the mass off collected particulate and the volume of air sampled.
Apparatus : High Volume Sampler
: GFA Filters
: Analytical Balance
|
Nitrogen Dioxide
|
24 hours
|
Sampling Method: NO2 is trapped in absorbing reagent (CDR) using air metering device and analysed by Griess-Saltzman Reaction Method.
Apparatus : Air Metering Device,
: Impingers with absorbing reagents
: Spectrophotometer
|
Sulphur Dioxide
|
24 hours
|
Sampling Method: SO2 is trapped in absorbing reagent (TCM) using air metering device and analysed by TCM/Pararosaniline method.
Apparatus : Air Metering Device,
: Impingers with absorbing reagents
: Spectrophotometer
|
Carbon Monoxide
|
24 hours
|
Sampling Method: Diffusion Sampling
Apparatus: Gastec Passive Dosi-Tube for CO
|
Wind Velocity
|
Direct Reading
|
Sampling Method: Direct measurement
Apparatus: Anemometer, Model AM 4202
|
Relative Humidity
|
Direct Reading
|
Sampling Method: Direct measurement
Apparatus: G.H Zeal Limited, ZEAL Digital Thermo Hygro, Model P2540 (20/95% Relative Humidity and 50/70 Deg.C).
|
Air Temperature
|
Direct Reading
|
Sampling Method: Direct measurement